A column separates proteins only when its beads distinguish something about them. First identify the property that differs—size in solution, net charge at the chosen pH, or binding to a ligand. Then decide which proteins stay on the column and which leave first. The worked problems below also show how to judge whether a purification step was worth the loss of target protein.

Charge is the key to ion exchange. In BiochemDrill’s free amino acid chapter, practice how pH changes lysine’s charge before predicting which resin will bind a protein.

Try the free charge activity

Three questions, three separation methods

What the column distinguishes
MethodWhat the beads doUseful prediction
Size exclusion (gel filtration)Porous beads admit smaller molecules; larger ones take the shorter path around the beads.For similarly shaped, noninteracting proteins within the column’s range, the larger one elutes first.
Ion exchangeCharged groups on beads bind proteins with the opposite net charge at the buffer pH.A negative resin (cation exchanger) binds a positive protein; a positive resin (anion exchanger) binds a negative protein. Salt or pH changes can elute bound protein.
AffinityAn immobilized ligand selectively holds a protein with a matching binding site or engineered tag.The target stays while many other proteins flow through; a suitable competitor or condition change releases it.

“Elutes first” depends on the method. In size exclusion, early elution often means large. In ion exchange or affinity, an early flow-through fraction often contains the proteins that did not bind. Keep the flow-through, wash, and elution fractions conceptually separate.

Four worked examples

1. Read a size-exclusion chromatogram

A mixture contains compact, nonaggregating proteins of 150, 60 and 15 kDa. All three fall within the column’s fractionation range and do not stick to the beads. Which peak appears first?

Answer: 150 kDa, then 60 kDa, then 15 kDa. The largest protein enters the fewest pores, travels the shortest route and emerges first. The 15 kDa protein explores more pore volume and emerges last. Mass works as a size proxy here because the problem specifies similarly shaped proteins; unusual shape or aggregation can change the order.

2. Pick the ion exchanger at pH 7

Protein A has pI 8.5 and protein B has pI 5.2. At pH 7, a negatively charged cation-exchange resin is loaded in a low-salt buffer. Which protein is expected to bind?

Answer: A binds; B is more likely to flow through. Below its pI, A has a net positive charge, so it is attracted to the negative resin. Above its pI, B has a net negative charge and is not attracted to that resin. After washing, raising salt can weaken the electrostatic interaction and elute A. Real binding also depends on buffer, accessible surface charges and resin conditions, so pI gives a first prediction rather than a guarantee.

3. Follow a tagged protein through affinity chromatography

A recombinant protein carries a His tag. It is loaded on a nickel-binding resin. The desired protein is missing from the early flow-through but appears after imidazole is added. Did the target disappear?

Answer: No. The His tag held the protein on the resin during loading and washing; imidazole competed for the metal-binding sites and released it. Compare the target assay in the flow-through, wash and elution fractions before deciding where the target went. A strong elution peak alone does not prove the fraction is perfectly pure.

4. Calculate purity and recovery from a purification table

A crude extract has 1,200 mg total protein and 6,000 units of target-enzyme activity. After ion exchange, the pooled fraction has 180 mg and 4,500 units. After size exclusion, it has 50 mg and 3,500 units. What are the specific activity, purification fold and yield after each step?

Specific activity = total target activity ÷ total protein; fold = step specific activity ÷ crude specific activity; overall yield = step total activity ÷ crude total activity × 100%.

Checked calculations, using the crude extract as baseline
FractionSpecific activity (units/mg)Overall foldOverall yield
Crude6,000 ÷ 1,200 = 51×100%
Ion exchange4,500 ÷ 180 = 2525 ÷ 5 = 5×4,500 ÷ 6,000 = 75%
Size exclusion3,500 ÷ 50 = 7070 ÷ 5 = 14×3,500 ÷ 6,000 ≈ 58.3%

The final fraction has higher specific activity, but only about 58% of the starting activity remains. Fold and yield answer different questions: enrichment of the target relative to all protein, and recovery of the target’s measured activity.

Check yourself

Choose an answer and check your reasoning. Then try the other predictions before opening their answers.

A 90 kDa protein and a 25 kDa protein have similar shapes and do not stick to the beads. Which elutes first from a suitable size-exclusion column?

1. A 90 kDa protein and a 25 kDa protein differ only in size. Which one elutes first from a suitable size-exclusion column?

90 kDa. The larger protein explores less bead pore volume. This assumes similar shapes and no unwanted binding.

2. At pH 8, a protein with pI 6.0 is net negative. Which resin is the first ion-exchange choice to bind it?

An anion exchanger with positively charged groups. It binds negatively charged proteins. The exchanger is named for the mobile ion it binds, not for the resin’s own charge.

3. A target enzyme binds an affinity column while most other proteins leave in the wash. Which fraction should you assay after adding a competing ligand?

The elution fraction. Competition releases the bound target. Also assay the load, flow-through and wash to check for losses.

4. A crude fraction has 400 units in 80 mg; a final fraction has 240 units in 12 mg. Find the final specific activity, overall fold and yield.

20 units/mg, 4×, 60%. Crude specific activity = 400 ÷ 80 = 5 units/mg; final = 240 ÷ 12 = 20; fold = 20 ÷ 5 = 4; yield = 240 ÷ 400 × 100% = 60%.

Common mistakes

  • Reversing size-exclusion order: the larger protein usually exits first because it bypasses bead pores. That is different from migration through an SDS-PAGE gel.
  • Naming an exchanger by its resin charge: a cation exchanger carries negative groups and binds cations; an anion exchanger carries positive groups and binds anions.
  • Using pI as an exact binding switch: pH relative to pI predicts the sign of net charge, while salt, local charge and buffer conditions affect real binding.
  • Confusing purity with yield: a higher specific activity can come with a lower total target activity. Report both fold enrichment and activity recovered.
  • Calling a single affinity peak “pure” without checking: binding is selective, but contaminants can coelute. Compare fractions with a target assay and an appropriate analysis method.

Frequently asked questions

Which protein elutes first in size-exclusion chromatography?

For similarly shaped proteins within the column's separation range, the larger protein elutes first because it enters fewer bead pores and travels a shorter path.

Does a cation exchanger bind positive or negative proteins?

A cation exchanger has negatively charged groups and binds positively charged proteins under suitable buffer conditions. Salt or pH changes can release a bound protein.

How do you calculate purification fold and overall yield?

Divide a fraction's specific activity by the crude fraction's specific activity to find overall purification fold. Divide its total target activity by the crude fraction's total target activity and multiply by 100% to find overall yield.

Textbook sources

The numbers and scenarios above are original teaching examples, not experimental results from the sources.

Practice charge and pH in the free amino acid chapter, then return to predict which protein a column will retain.

Try the free charge activity